Material Recovery Facility: Difference between revisions

From WikiWaste
m (minor text change)
Line 16: Line 16:


==Types of MRF==
==Types of MRF==
There are essentially three broad types of MRF:
There are essentially four broad types of MRF:
*'''"Clean" MRFs''' that accept materials from source separation schemes and [[Dry Mixed Recyclables]] ([[DMR]]).  
*'''"Single-Stream" MRFs''' that are focused on one [[recyclate]] stream, removing any contamination/contrary materials from that material to produce a high quality [[recyclate]] with high value.
*'''"Dirty" MRFs'''/'''Waste to Fuel MRF''' which extract recyclables from mixed [[MSW]] and [[Commercial Waste]] streams and are generally more focused on producing a [[Waste Derived Fuel]] ([[WDF]]).  
*'''"Clean" MRFs''' that are focused on [[Dry Mixed Recyclables]] ([[DMR]]). They remove contamination/contrary materials of up to c. 20% in the input mix (in the worst cases) and produce a variety of separate good quality [[recyclate]] streams with less than c.2% contrary materials with good value.
*'''"Dirty" MRFs'''/'''Waste to Fuel MRF''' which extract some [[recyclate]] from mixed [[MSW]] and [[Commercial Waste]] streams with more of a focus on producing a [[Waste Derived Fuel]] ([[WDF]]). [[Recyclate]] tends to be of poor quality and of lower value.  
*'''Material specific MRFs''' for example:
*'''Material specific MRFs''' for example:
**[[Construction and Demolition Waste]] and skip wastes
**[[Construction and Demolition Waste]] and skip wastes.
**[[Waste Electrical and Electronic Equipment]]
**[[Waste Electrical and Electronic Equipment]]
**[[Plastic]] materials and purpose designed '''[[PRF]]s''' ([[Plastics Recovery Facility]] or [[Plastics Recovery Facility | Plastics Recycling Facility]])
**[[Plastic]] materials and purpose designed '''[[PRF]]s''' ([[Plastics Recovery Facility]] or [[Plastics Recovery Facility | Plastics Recycling Facility]])

Revision as of 06:59, 25 February 2022

A Material Recovery Facility is often referred to as a ‘MRF’ and is generically a facility that sorts, grades and prepares waste fractions suitable for onward dispatch to a Reprocessor.

Picture of Machinex DMR MRF, courtesy of Machinex, all rights reserved
Picture of Machinex DMR MRF, courtesy of Machinex, all rights reserved


Overview

A Material Recovery Facility is often referred to as a ‘MRF’ and is generically a facility that sorts, grades and prepares waste fractions suitable for onward dispatch to a Reprocessor. Many also refer to a MRF as a Material Recycling Facility, which is not strictly true in that the MRF separates the material for onward recycling rather than recycling the material in its own right.

The key elements of MRF design and operation include:

  • Throughput capacity - measured in both weight and volume due to differing bulk densities of materials that impact on the design of the sorting machinery, capacity of conveyors and storage areas
  • Reliability - the operational availability of the plant and the time required to maintain it
  • Quality of Outputs - high quality outputs ensure a solid, higher value market for the materials recovered
  • Adaptability - the ability to adjust to changing inputs over time

In all of these factors, the quality of the input materials clearly has a major influence. Poor quality materials, or materials that are heavily contaminated at the input stage, can lead to lower quality outputs and/or higher levels of rejects as part of the process.

Types of MRF

There are essentially four broad types of MRF:

"Clean" MRFs

"Clean" MRFs accept materials from source separation schemes and Dry Mixed Recyclables (DMR). A pictorial overview of one type layout/configuration is shown below for multiple streams of DMR, whereas a single stream or twin stream input would have a far more straightforward layout[1]:

MRF Diagram 1. Material Feed - often delivered via a Bag Breaker
2a.Trommel/Trommel Screen - normally used to separate off the larger, lighter mixed paper and cardboard fractions from the other materials
2b.Ballistic Separator - normally used to separate 2-dimensional light and flat items (such as paper and cardboard) from 3-dimensional heavier rigid items such as glass bottles and cans
3a.Magnetic Separator - used to separate steel cans/ferrous metals
3b.Air Separator/Air Classifier - used to separate heavy from light materials, in this case to remove contamination from the glass fraction
4.Eddy Current Separator - used to separate aluminium cans/non-ferrous metals
5.NIR Optical Sorting - Near Infra Red (NIR) light is used to separate materials, often focused on different plastic types/polymers

The MRF Code of Practice applies to all 'Qualifying MRFs' which are those all those MRFs that receive more than 1,000 tonnes per annum of primarily DMR materials from households and other sources with a similar composition. This has allowed the performance of MRFs to be compared, including the level of contamination and associated rejects from each MRF. A full list of these sites can be found on the page Qualifying MRFs.

"Dirty MRFs"

content to follow

Material Specific MRFs

Construction and Demolition Waste and Skip Wastes

content to follow

Waste Electrical and Electronic Equipment

content to follow

Plastic Materials and Purpose Designed PRFs

content to follow

References

  1. Suez Recycling and Recovery UK