Also known as Biomass UK No 1, Hull Energy Production Facility is a Biomass EfW facility based on Wood Waste designed to generate 11.7MWe (export 10MWe) of power[1].


Hull Energy Production Facility
Under Construction
Site Location
Site Location

See Biomass EfW → page for a larger UK Wide map.

Operator Biomass UK No1 LLP
Capacity 10 MWe
Feedstock Waste Wood/RDF
EPR (Waste Licence) DP3932RS
ROC No
CfD
CHP Unkwn

Operators Annual Report


Input Data

Year Wood Litter RDF Other Total
2019 9777 0 0 0 9777
2021 10485 0 0 0 10485
2022 9550 0 6629 0 16179


Output Data

Year IBA IBA %ge of Tot IN APC APC %ge of Tot IN
2021 108 1.03% 288 2.75%
2022 292 1.80% 915 5.66%

Summary

Also known as Biomass UK No 1, Hull Energy Production Facility is a Biomass EfW facility based on Wood Waste designed to export 10MWe of power[2]. The plant was developed by Aviva Investors who also developed Biomass UK No 2 (Barry Dock) and No3 (Boston Energy Production Facility) [3].

Plant

The plant is based on a gasification technology via a Fluidised Bed with power generation via a steam boiler and turbine designed to process up to 86,400 tonnes per annum at a nominal capacity of 10.8 tonnes per hour. The plant remainder closed much of 2021 to allow for an upgrade programme and operated at 15% of capacity in the year[4].

Annual Sustainability Tonnage Input/Fuel

The tonnage[5] received by the plant in the most recent Annual Sustainability Report and for the previous 3 years for 2020/21 was reported by Ofgem as below[6]:

Year Waste Wood (m3) Waste Wood (t) Straw Miscanthus Arboricultrual Waste Sawmill Residue Foresrty Residue Round Wood Short Rotation Coppice MBM Other Material
2020/21 94783096 0 0 0 0 0 0 0 0 0 0
2019/20 66652208 0 0 0 0 0 0 0 0 0 0
2018/19 0 0 0 0 0 0 0 0 0 0 0
2017/18 0 0 0 0 0 0 0 0 0 0 0

The query SELECT "updated" FROM "db_ea"."ea_ew_in" WHERE epr='DP3932RS' LIMIT 1 is invalid (Error : SSL SYSCALL error: EOF detected

Function: EDConnectorRdbms::fetch Query: SELECT "updated" FROM "db_ea"."ea_ew_in" WHERE epr='DP3932RS' LIMIT 1 ).Error: Could not connect to database (Cannot access the database: Unable to connect to PostgreSQL server: connection to server at "10.106.0.2", port 5432 failed: FATAL: the database system is in recovery mode).Error: Could not connect to database (Cannot access the database: Unable to connect to PostgreSQL server: connection to server at "10.106.0.2", port 5432 failed: FATAL: the database system is in recovery mode).

Waste Tonnage, By Origin

The table shows a list of the Waste for the Permit DP3932RS, that has arrived into sites as reported to the Regulator and then publicised in their reported statistics. The Data used is from the most recent returns. The total reported tonnage arriving at the site was: Expression error: Unexpected < operator.t.

Where this tonnage exceeds that reported in year of the corresponding annual report, this may be due to the following reasons:

  • Tonnage may have been received but not incinerated, i.e. the material is held pending incineration (the operator return to the EA reports as received whereas the annual report focuses on when the waste is incinerated.)
  • Material may have been received into the site but treated in some other way than incineration.
  • Material may have been received on the but transferred out of site for disposal/treatment at another site rather than incineration on the site.
EWC Code Origin of Waste Tonnes In